Item # Cermet II I.S., Cermet II I.S. Self-Contained Hygrometers on Michell Instruments, Inc.
Michell Instruments, Inc. - Item # Cermet II I.S., Cermet II I.S. Self-Contained Hygrometers
Javascript Menu by Deluxe-Menu.com
Home
Products
By Technology
Chilled Mirror
Impedance
Calibration and Humidity Generation
Quartz Crystal Microbalance
Thermo-Paramagnetic Oxygen Sensor
Hydrocarbon Dew Point Dark Spot Principle
Capacitive Technology
Michell Zirconium Oxide Oxygen Sensor
By Industry
Aerospace
Automotive
Beverage Industry
Breathing Air
Compressed Air
Drying of Plastics
Environment
General Engineering
General Gases
Metals and Heat Treatments
Metrology
Military / Defense
Natural Gas & Petrochemicals
Pharmaceutical / Confectionery
Power Generation
Process Industries
Research & Development
Semi-Conductor / Electronics
By Category
Process Analyzers
Calibration Instruments
Portable Instruments
Dew-Point Transmitters
Chilled Mirror Instruments
Relative Humidity Products
Oxygen Analyzers
About Us
News
Exhibitions
Links
Accreditations
Support
Application Notes
Software Downloads
Support Request
Newsletter Registration
Contact Us
Search Catalog
By Keyword
By Item #
All Categories
Cermet II I.S. Self-Contained Hygrometers
|
Shipping
|
Tax
|
Terms
Shopping Cart
0 Items
Request for Quote
0 Items
All Categories
>
Dew-Point Transmitters
>
Cermet II I.S. Self-Contained Hygrometers
>
Item # Cermet II I.S.
Download PDF
Printable Page
Email This Page
Save To Favorites
Cermet II I.S. Self-Contained Hygrometers
QUOTE
Download PDF
Email This Page
Save To Favorites
Cermet II I.S. is an easy to install, self-contained hygrometer system for measurement of the moisture content of flammable and non-flammable gases within hazardous areas. It consists of a safe area Cermet II I.S. Control Unit and an intrinsically safe transmitter, the Transmet I.S. Housed in a stainless steel case, the Transmet I.S. transmitter is rated NEMA 4X. The Cermet II I.S. Control Unit is a 19" rack-mount unit containing the display, transmitter power supply and isolation barriers suitable for location in a designated safe area. It provides all necessary user interfacing, including multiple units of measure display, alarms, analog and digital outputs. Control unit and transmitter are connected by up to 1500 feet of cable using galvanic isolation barriers.
larger image
larger image
Sensor
·
Control Unit Options
·
Transmet I.S. Transmitter
·
Interconnecting Sensor Cable Options
Sensor
Measurement Range
-148 to +68ºF dew point
Accuracy
±1ºC from +20 to -60ºC dew point (±1.8ºF from +68 to -76ºF dew point)
±2ºC from -60 to -100ºC dew point (±3.6ºF from -76 to -238ºF dew point)
Other Units of Measurement
Digital processing and linearization with pressure compensation from measured dew point with pressure compensation to any other selected unit - lb/mmscf and mg/m
3
(for natural gas), ppm
V
with active or passive pressure compensation
Pressure Input
Fixed value (user programmed) or dynamic measurement with an optional 4-20 mA pressure transmitter
Resolution
0.1ºF dp, 0.01 ppm
V
, 0.1 mg/m
3
, 0.01 lb/mmscf
Analog Outputs
4-20 mA isolated (max load 500 Ω)
Sensor Calibration
Traceable to NIST
Power Requirement
85 to 264 VAC, 50/60 Hz or 90 to 370 VDC
Alarms
Two user adjustable isolated 10A @ 240 VAC or 24 VDC: 8 A (non-inductive load) for set points and fault detection
Mounting Panel
19" anodized aluminum, 5.197" high x 7" clearance depth
Additional Power Supply Unit
24 VDC clip-on rail type for Transmet IS
Barriers
2 galvanic isolation type
Control Unit Options
Power Supply
Low voltage version 18 to 36 VAC; 9 to 60 VDC
Relays
1 or 2 additional 5 A relays (max 4 total) n/o type fully user configurable and adjustable over the full range, full choice of units and sensor fault alarm functions
Analog Outputs
0-10 V fully user configurable and scaleable
Digital Outputs
RS485: provides 2-way communication - full data access to user and total availability of all set-up and configuration
Transmet I.S. Transmitter
Process Connection
5/8" UNF parallel thread
Enclosure
Stainless steel
Ingress Protection
NEMA 4X
Power
Provided by Cermet II I.S control unit
Operating Temperature
-20 to +60 ºC
-4 to +140 ºF
Storage Temperature
-40 to +70 ºC
-40 to +158 ºF
Maximum Operating Pressure
From vacuum to 300 barg
From vacuum to 4351 psig
Flow Rate
0-10 Nlmin
-1
(0-21 CFM) at atmospheric pressure
Gas Velocity
20 m/s
-1
(65.6 FPS) (max) at atmospheric pressure
Interconnecting Sensor Cable Options
Field cable specification: Polyethylene insulated instrumentation cable to BS5308 Part 1 - two collectively shielded dual conductors 0.5 mm2. Polyethylene insulation, galvanized steel wire armor, and PVC flame retardant outer sheath in blue. Low smoke and fume or halogen free outer sheath options available Max length: 1500 foot (greater dependent upon cable specification)
© Copyright Michell Instruments Inc.