S8000 Integrale Chilled Mirror Hygrometers

QUOTE


    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  


The new S8000 Integrale continues Michell’s tradition of excellence in the design of high performance products. This new generation of Michell hygrometers/dew point meters offers unmatched accuracy and repeatability in dew point measurement of air and gas systems in laboratories and many field applications. With its powerful state of the art thermoelectric heat pump the S8000 Integrale can precisely measure at dew points down to -60ºC (-76ºF). The integrated sensor head allows the instrument to function as a standalone instrument. Available in the vertical and horizontal configuration the S8000 Integrale can also be supplied in a rugged transportable case.

S8000 Integrale Chilled Mirror Hygrometers

larger image

S8000 Integrale Chilled Mirror Hygrometers-2

larger image



General · Dew-Point Sensor · Flow Sensor · Display Unit · Optional Remote PRT · Optional Pressure Sensor (In-Built)

General

Measurement Range

-60 to +40ºCdp (-76 to +104ºFdp)

Measurement Accuracy1

±0.1ºCdp (±0.18ºFdp)

Stability

Better than 0.1ºCdp (0.18ºFdp)

Repeatability

<0.05 ºC
0.16 ºF

Measurement Units

ºCdp or ºFdp; % RH; g/m3; g/kg; ppmV; ppmW, SF6; ml/min

Response Speed

2ºC/sec + settling time (3.6ºF/sec)

Power Supply

85 to 264 V, 47/63 Hz; 100 VA

Operating Temperature Range

-20 to +50 ºC
-4 to +122 ºF
1 Measurement accuracy means maximum deviation between instrument under test and corrected reference. To this must be added the uncertainties associated with the calibration system and the environmental conditions during testing or subsequent use.


Dew-Point Sensor

Mirror

Gold plated copper

Temperature Measurement

4 wire Pt100, 1/10 DIN class B

Pressure1

1.7 MPa (17 barg/246.56 psig)
1 For higher pressure consult factory


Flow Sensor

Measurement Range

0 to 1000 mL/min
0 to 2118.88 scfh


Display Unit

Resolution

User-selectable to 0.001 dependant on parameter

Analog Outputs

Three channels; user-selectable 4-20 mA, 0-20 mA or 0-1 V

Digital Outputs

USB, SD Card slot

Alarm Outputs

Two volt free changeover contacts, one process alarm, one fault alarm; 1 A @ 30 VDC

Cable Pack

Supply and USB cables. Output connectors suitable for indoor use


Optional Remote PRT

Temperature Measurement

4 wire Pt100, 1/10 DIN class B

Measurement Accuracy1

±0.1 ºC
±0.18 ºF

Measurement Units

ºC or ºF

Cable Length

2 m
6.56 ft

Maximum Cable Length

250 m
280.21 ft
1 Measurement accuracy means maximum deviation between instrument under test and corrected reference. To this must be added the uncertainties associated with the calibration system and the environmental conditions during testing or subsequent use.


Optional Pressure Sensor (In-Built)

Measurement Range

2.5 MPa
25 barg
362.59 psia

Measurement Accuracy1

0.25 % Full Scale, typical Measurement units

Measurement Units

barg; psig; Kpg; MPa
1 Measurement accuracy means maximum deviation between instrument under test and corrected reference. To this must be added the uncertainties associated with the calibration system and the environmental conditions during testing or subsequent use.