Item # S8000, S8000 Integrale Chilled Mirror Hygrometers on Michell Instruments, Inc.
Michell Instruments, Inc. - Item # S8000, S8000 Integrale Chilled Mirror Hygrometers
Javascript Menu by Deluxe-Menu.com
Home
Products
By Technology
Chilled Mirror
Impedance
Calibration and Humidity Generation
Quartz Crystal Microbalance
Thermo-Paramagnetic Oxygen Sensor
Hydrocarbon Dew Point Dark Spot Principle
Capacitive Technology
Michell Zirconium Oxide Oxygen Sensor
By Industry
Aerospace
Automotive
Beverage Industry
Breathing Air
Compressed Air
Drying of Plastics
Environment
General Engineering
General Gases
Metals and Heat Treatments
Metrology
Military / Defense
Natural Gas & Petrochemicals
Pharmaceutical / Confectionery
Power Generation
Process Industries
Research & Development
Semi-Conductor / Electronics
By Category
Process Analyzers
Calibration Instruments
Portable Instruments
Dew-Point Transmitters
Chilled Mirror Instruments
Relative Humidity Products
Oxygen Analyzers
About Us
News
Exhibitions
Links
Accreditations
Support
Application Notes
Software Downloads
Support Request
Newsletter Registration
Contact Us
Search Catalog
By Keyword
By Item #
All Categories
S8000 Integrale Chilled Mirror Hygrometers
|
Shipping
|
Tax
|
Terms
Shopping Cart
0 Items
Request for Quote
0 Items
All Categories
>
Chilled Mirror Hygrometers
>
S8000 Integrale Chilled Mirror Hygrometers
>
Item # S8000
Download PDF
Printable Page
Email This Page
Save To Favorites
S8000 Integrale Chilled Mirror Hygrometers
QUOTE
Download PDF
Email This Page
Save To Favorites
The new S8000 Integrale continues Michell’s tradition of excellence in the design of high performance products. This new generation of Michell hygrometers/dew point meters offers unmatched accuracy and repeatability in dew point measurement of air and gas systems in laboratories and many field applications. With its powerful state of the art thermoelectric heat pump the S8000 Integrale can precisely measure at dew points down to -60ºC (-76ºF). The integrated sensor head allows the instrument to function as a standalone instrument. Available in the vertical and horizontal configuration the S8000 Integrale can also be supplied in a rugged transportable case.
larger image
larger image
General
·
Dew-Point Sensor
·
Flow Sensor
·
Display Unit
·
Optional Remote PRT
·
Optional Pressure Sensor (In-Built)
General
Measurement Range
-60 to +40ºCdp (-76 to +104ºFdp)
Measurement Accuracy
1
±0.1ºCdp (±0.18ºFdp)
Stability
Better than 0.1ºCdp (0.18ºFdp)
Repeatability
<0.05 ºC
0.16 ºF
Measurement Units
ºCdp or ºFdp; % RH; g/m
3
; g/kg; ppm
V
; ppm
W
, SF
6
; ml/min
Response Speed
2ºC/sec + settling time (3.6ºF/sec)
Power Supply
85 to 264 V, 47/63 Hz; 100 VA
Operating Temperature Range
-20 to +50 ºC
-4 to +122 ºF
1
Measurement accuracy means maximum deviation between instrument under test and corrected reference. To this must be added the uncertainties associated with the calibration system and the environmental conditions during testing or subsequent use.
Dew-Point Sensor
Mirror
Gold plated copper
Temperature Measurement
4 wire Pt100, 1/10 DIN class B
Pressure
1
1.7 MPa (17 barg/246.56 psig)
1
For higher pressure consult factory
Flow Sensor
Measurement Range
0 to 1000 mL/min
0 to 2118.88 scfh
Display Unit
Resolution
User-selectable to 0.001 dependant on parameter
Analog Outputs
Three channels; user-selectable 4-20 mA, 0-20 mA or 0-1 V
Digital Outputs
USB, SD Card slot
Alarm Outputs
Two volt free changeover contacts, one process alarm, one fault alarm; 1 A @ 30 VDC
Cable Pack
Supply and USB cables. Output connectors suitable for indoor use
Optional Remote PRT
Temperature Measurement
4 wire Pt100, 1/10 DIN class B
Measurement Accuracy
1
±0.1 ºC
±0.18 ºF
Measurement Units
ºC or ºF
Cable Length
2 m
6.56 ft
Maximum Cable Length
250 m
280.21 ft
1
Measurement accuracy means maximum deviation between instrument under test and corrected reference. To this must be added the uncertainties associated with the calibration system and the environmental conditions during testing or subsequent use.
Optional Pressure Sensor (In-Built)
Measurement Range
2.5 MPa
25 barg
362.59 psia
Measurement Accuracy
1
0.25 % Full Scale, typical Measurement units
Measurement Units
barg; psig; Kpg; MPa
1
Measurement accuracy means maximum deviation between instrument under test and corrected reference. To this must be added the uncertainties associated with the calibration system and the environmental conditions during testing or subsequent use.
© Copyright Michell Instruments Inc.