Item # S4000, S4000 Remote Chilled Mirror Hygrometers on Michell Instruments, Inc. Michell Instruments, Inc. - Item # S4000, S4000 Remote Chilled Mirror Hygrometers
Search Catalog 
      GO   
 All Categories    S4000 Remote Chilled Mirror Hygrometers
View CartView RFQ'sExpress Ordering  | Shipping 
 | Tax 
 | Terms 
 Shopping Cart  0 Items 
 Request for Quote  0 Items 
All Categories > Chilled Mirror Hygrometers > S4000 Remote Chilled Mirror Hygrometers > Item # S4000  
    Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Request Information

S4000 Remote Chilled Mirror Hygrometers

QUOTE


    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  


The S4000 Remote Precision Dew-point meter offers unmatched accuracy and reliability in dew-point measurements of air and gas systems and in calibration laboratories. Its powerful three stage Peltier thermoelectric heat pump gives a depression capability of more than 80ºC (176ºF) at normal laboratory temperature. The S4000 Remote can measure and control at dew points (frost points) down to -50ºC (-58ºF) from a normal room temperature, and with additional water-cooling through the integral cooling jacket can measure as low as -80ºC (-112ºF) dew point. As its name suggests, the S4000 Remote comprises a free-standing sensor and a 19" x 3 U monitor unit, connected by individual power and signal cables for the most stable and precise dew point control.

S4000 Remote Chilled Mirror Hygrometers

larger image

S4000 Remote Chilled Mirror Hygrometers-2

larger image



Performance · Electrical Input/Output · Output Ranges · Operating Conditions · Mechanical Specification

Performance

Measurement Technology

Chilled Mirror

Measurement Units

ºCdp, ºFdp; ºC, ºF temp; % RH, ppmv, ppmw, g/m3, g/kg, ppmw for SF6

Measurement Range

-80 to +20ºCdp (-112 to +68ºFdp) (remote);
-80 to +85ºCdp (112 to +185ºF) (climatic sensor)

Accuracy

±0.1ºCdp (0.18ºFdp) (typical system accuracy)

Sensitivity

0.01 ºC
0.018 ºF

Response Speed

0.5ºC/sec + setting time (0.9ºF) (dew point dependent)

Repeatability

Better than 0.1ºC (0.18ºF)

Recommended Sample Flow Rate

0.1 to 0.7 L/min
0.2 to 1.5 scfh

Sensor Pressure

0.1 MPa
1 barg
14.5 psig


Electrical Input/Output

Analog Outputs

10 mV/ ºCdp, 4-20 mA

Digital Outputs

RS232: data hold, ABC status, optics alarm (logic)


Output Ranges

Display Resolution

0.01 for all units

Power Supply

90 to 265 VAC; 50-60 Hz (monitor)


Operating Conditions

Sensor Operating Temperature

-30 to +30 ºC (-22 to +86 ºF) (remote)
-30 to +90 ºC (-22 to +194 ºF) (climatic)


Mechanical Specification

Sensor Housing Type

Bench case; space frame (climatic version)

Dimensions (W X D X H)

268 x 300 x 133 mm
10.6 x 11.8 x 5.2 in

Weight

5.5 kg; 4.8 kg (climatic version)
12.1 lb; 10.6 lb (climatic version)

Maximum Cable Length

50 m
164 ft

Display

Dual 6 digit LED, with 2 digit eng unit indicators

Dual Optics Detection System

Wide band red LED with dual photo sensors

Integrated Flowmeter

0 to 1 L/min
0 to 2 scfh


Request Information